获取短信验证码
2025-01-07
作者:罗朝辉
下站防断轴故障
该索道为双承载单牵引往复式索道,2018年8月投入运营。
某日下午,索道正常启动时,按下“启动准备开”按钮后,出现下站防断轴;随即对防断轴触断针进行了检查,发现触断针正常、接触良好;复位后正常运行,索道运行一天后重复出现此故障。
处理过程
1.对防断轴触断针进行检查;发现触断针正常;
2.第一反应可能是PLC误故障,对PLC进行了重启,故障还是间断性出现;
3.通讯电缆接线端子,端子紧固无锈蚀;防雷开关工作正常;

4.检查PLC电源,电源电压正常;
5.检查该故障回路继电器,继电器正常;
6.再次检查触断针,发现防断轴检测板的圆孔较小、距触断针间隙约1mm左右;
7.怀疑此故障可能是因为,在索道运行中产生的震动导致触断针接地引起的。
分析
1.该索道采用重锤张紧,由于导向轮与导轨间隙比较大;
2.该索道全线总长740米,全线设置一个夹索器;在运行时重锤箱移动幅度较大;
3.故障点检测板开孔较小。
结论
定期对触断针开关进行功能测试。